© Copyright 2004. All rights reserved.
  1. Star Water Systems S1101 User Manual Software
  2. Star Water Systems S1101 User Manual Instructions

Acquire the Star Water Systems 32,000-Grain Tannin Filter Water Softener S11TS32DR, programmable valve offers a 5 GPM water flow at 15 psi drop and it removes 4.0 parts per million of iron for clearer water at The Home Depot. Shallow well jet pump. Read online or download PDF. Star Water Systems EL10S User Manual. Manuals Directory ManualsDir.com - online owner manuals library. Star Water Systems manuals. Manual Star Water Systems EL10S User Manual Shallow well jet pump.

INSTALLATION IN STRUC TIONS
1. To reduce the risk of elec tri cal shock, a prop er ly ground ed
receptacle of grounding type must be in stalled and pro tect ed
by a ground fault circuit in ter rupt er (GFCI) and in ac cor dance
2. Make certain that the receptacle is with in the reach of the pump’s
pow er supply cord. DO NOT USE AN EX TEN SION CORD.
Extension cords that are too long or too light do not deliver
suf cient voltage to the pump motor. But more im por tant, they
could present a safety hazard if the insulation were to become
damaged or the con nec tion end were to fall into the sump.
3. Testing for Ground. As a safety mea sure, each elec tri cal outlet
should be checked for ground using an Un der writ ers Lab o ra to ry
Listed circuit analyzer which will in di cate if the pow er, neutral
and ground wires are correctly con nect ed to your out let. If they
4. For Added Safety. Pump must be con nect ed to a 3-prong
ground ed outlet in ter rupt er de vice (ground fault cir cuit in ter -
5.FOR YOUR PROTECTION, ALWAYS DIS CON NECT PUMP
phase pumps are supplied with a 3-prong ground ed plug to help
protect you against the pos si bil i ty of elec tri cal shock. DO NOT,
PIN. To re duce the risk of electrical shock, a properly grounded
re cep ta cle of ground ing type must be installed and pro tect ed
by a ground fault circuit interrupter (GFCI) in ac cor dance with
6. Installation and checking of electrical cir cuits and hard ware
should only be performed by a qualifi ed licensed electrician.
7. Risk of electric shock - These pumps have not been in ves ti gat ed
8. According to the state of California (Prop 65), this product
contains chemicals known to the state of California to cause
cancer and birth defects or other reproductive harm.
1. Check to be sure your power source is adequate for handling
the voltage requirements of the motor, as in di cat ed on the
2. Make sure the pump electrical supply cir cuit is equipped with
fuses or circuit breakers of proper ca pac i ty. Asep a rate branch
circuit is rec om mend ed, sized ac cord ing to the National Elec-
tri cal Code for the current shown on the pump name plate.
3. All plumbing (discharge and vent lines) must be in stalled to
meet local codes. Unit must be vented. DO NOT USE AN
'PRO-VENT'. Some states require this product to be installed
4. Repair and service should be performed by an au tho rized
5. CHECK VALVE MUST BE USED TO RE DUCE UN NEC -
chased sep a rate ly.
6. Dewatering pumps are not designed or intended for han dling
7. Maximum operating temperature must not exceed 77°F
8. For health reasons, do not unplug, turn off, or disable pump
and use pump tank system as a way to fill up a sink or laundry
9. Unit is designed for above ground installation only.
NOTE: Pumps with the “UL” mark and pumps with the “US” mark
are tested to UL Standard UL778. CSA Certified pumps are
Notice to Installer: Instructions must remain with installation.
Product information presented here re fl ects con di tions at time of publication. Consult factory re gard ing dis crep an cies or in con sis ten cies.
1104
0704
“Quality Products since 1866”
1-800-345-9422
DATE CODE: __________________
1. Inspect your unit. Occasionally, prod ucts are dam aged during ship ment. If the unit is damaged, contact your dealer before using.
2. Carefully read the literature provided to familiarize yourself with specific details regarding installation and use. These materials should
SEE BELOW FOR LIST OF WARNINGS

Summary of content (8 pages)

Advertising

18

TROUBLESHOOTING

Problem

Possible Cause

Corrective Action

Pump will not

start or run.

Low voltage, blown fuse open circuit.

Have a qualified electrician check fuse

and circuit.

Impeller bound.

Contact an Authorized Service Station.

Motor or wiring shorted.

Contact an Authorized Service Station.

Faulty or stuck float switch

Remove lid and check float

Pump starts too

soon.

Float “ON” point is adjusted too low.

Raise the top float stop. Make sure the

float is between the two stops. Refer to

Testing Pump/Tank Section.

Water level

exceeds 4-1/2

in. before pump

turns on.

Float “ON” point adjusted to high.

Lower the top float stop. Make sure the

float is between the two stops.

Pump will not

shut off.

Debris under float.

Remove debris from around float.

Faulty float switch.

Contact an Authorized Service Station.

Float “Off” point adjusted too low.

Raise the bottom float stop. Make sure

the float is between the two stops. Refer

to Testing Section.

Pump operates

but delivers little

or no water.

Debris around intake.

Clean area around intake.

Blockage in discharge pipe.

Remove pipe and flush out debris.

Low or incorrect voltage.

Star Water Systems S1101 User Manual Software

Have a qualified electrician check house

wiring.

Damaged Impeller.

Contact an Authorized Service Station.

Incorrect float adjustment

Make sure the float is between the two

stops. Refer to Testing Section.

Pump is air locked.

Make sure vent hole on discharge pipe

is clear.

Vertical lift too high.

Change discharge piping or contact

tech. service.

Download 181 Elna Sewing Machine PDF manuals. User manuals, Elna Sewing machine Operating guides and Service manuals. This instruction manual is for the Elna Model 150 Sewing Machine. It contains 24 pages of information on how to thread, maintain, and operate the machine. This is a PDF Down-load-able Manual that you can print yourself or take to your local Office Supply Store or Print Shop and let them print and bind it for you. Our PDFs are set for printing. Elna Model 1500 Sewing Machine Instruction Manual, 33 Pages. The physical copy of the instruction manual is a soft cover printed photocopy. Java sun manual download Jul 30, 2013  Elna 1500 1600 Sewing Machine Service Manual. DOWNLOAD HERE. Elna 1500 1600 Sewing Machine Service Manual how to remove the front cover how to refit the front cover hook axle position and hook.

Pump runs

too long

before water is

Star Water Systems S1101 User Manual Instructions

pumped.

Pump is air locked.

Make sure vent hole on discharge pipe

is clear.

Water level too low.

Clear debris from around baffle. Make

sure the float is between the two stops.

Refer to Testing Section.